LOCUPD and Mobile to Mobile Call Database

DATABASE In MSC/VLR

# Acknowledment : In this case, we will use MSC/VLR Medan 10 and Medan 11, HLR Medan1, BSC Tembung and BSC Amir hamzah.

  • SPC MSC/VLR = 6317 NAT0
  • SPC MSC/VLR/HLR (Combine) = 6320 NAT0
  • SPC HLR = 6308 NAT0
  • SPC BSC = 6309 NAT0
  • SPC STP  = 6330 NAT0
  • GT VLR = 6281106047 (Combine)
  • GT HLR = 6281106047 (Combine)
  • GT HLR = 6281106048 (Not Combine)
  • LTG=1-55,,LDPARP=41; (Connection to BSC)
  • LTG=1-21,,LDPARP=46; (Connection to HLR if not combine)
  • A Sub = +62811600492, MSIN = 1000600492, IMSI=510101000600492
  • B Sub = +62811600493, MSIN = 1000600493, IMSI=510101000600493

Database Location Update:

As we know that the system of D900/1800 (Siemens Equipment for MSC/VLR) has CP (Coordination Processor) and SSNC ( Signaling System Network Control). So that some database located in CP and the other on SSNC. These database follow ed the rule of SS7 as guidance.

  • Creation MTP L1 (Physical) on CP:

CRLTG:LTG=1-55,TYPE=LTGB,LDPARP=41;

CRLTG:LTG=1-21,TYPE=LTGB,LDPARP=46;

CRLTU:LTG=1-55,LTU=0,TYPE=D30,APPLIC=CCSCCS;

CRLTU:LTG=1-21,LTU=1,TYPE=D30,APPLIC=CCSCCS;

  • Creation MTP2  (Data Link) on CP :

CRSIGDLLTG:Net ID=3,Data link “SBTBG#300”,Adjacent DPC=7421,MP=mpNo 4,Outward EQN=outwardEquipmentNumber eqn \: {part1 1,part2 55,part3 0,part4 16};

CRSIGDLLTG:Net ID=3,Data link “SHMDN1#300”,Adjacent DPC=7422,MP=mpNo 8,Outward EQN=outwardEquipmentNumber eqn \: {part1 1,part2 21,part3 1,part4 1};

CRSIGLINK:Link set,Link code=0,Data link,Protocol profile;

CRSIGLINK:Link set,Link code=0,Data link,Protocol profile;

  • Creation MTP L3 (Transport) on SSNC:

CRSIGPOINT:Net ID=3,Net,Signaling point step,Net indicator=National network 0,Alarm profile MP=”CRITICAL”,SPC=6317,TFP TFA broadcast=broadcastPerformanceIndicator restricted,TFR compatibility=tfrCompatibility FALSE;

CRSIGDP:Net ID=3,DPC,DPC=6308,Loadsharing key=none 0;

CRSIGDP:Net ID=3,DPC,DPC=6309,Loadsharing key=none 0;

CRSIGLSET:Net ID=3,Link set,Adjacent DPC=6308,Congestion method=Q704 international;

CRSIGLSET:Net ID=3,Link set,Adjacent DPC=6309,Congestion method=Q704 international;

CRSIGROUTE:Net ID=3,Link set,DPC=6308,Priority=flexiblePriority 1;

CRSIGROUTE:Net ID=3,Link set,DPC=6309,Priority=flexiblePriority 1;

  • Creation SCCP Own (Local) on SSNC:

CRSPLNKLOC:SPLNKLOC Name=”SELF-NAT0″,Net ID=3,SCLProtClasses=class0-class1,SCOProtClasses=class2-class3;CRSPSSN:SPLNKLOC Name=”SELF-NAT0″,SSN=6,SSID=ssid maphlr;CRSPSSN:SPLNKLOC Name=”SELF-NAT0″,SSN=7,SSID=ssid mapvlr;

CRSPSSN:SPLNKLOC Name=”SELF-NAT0″,SSN=8,SSID=ssid mapmsc;

CRSPSSN:SPLNKLOC Name=”SELF-NAT0″,SSN=254,SSID=ssid bssap;

CRSPAPLOC:SPAPLOC Name=”MAPVLR”,SSN=sap2Address 7,SSID=ssid mapvlr,VMS=vmzFlag noVmz;

CRSPAPLOC:SPAPLOC Name=”MAPMSC”,SSN=sap2Address 8,SSID=ssid mapmsc,VMS=vmzFlag noVmz;

CRSPAPLOC:SPAPLOC Name=”BSSAP”,SSN=sap2Address 254,SSID=ssid bssap,VMS=vmzFlag noVmz;

CRSPCLGPA:SPAPLOC Name=”MAPMSC”,SPCLGPA,Include SPC=includeSPC FALSE,Include GT=includeGt TRUE,CLGPA Type Indicator=cgaAddressTypeIndicator programmed,NA=gtNatureOfAddress international,TTID=gtTranslationTypeLocal unknown,NP=gtNumberingPlan iSDNTNP,SPLNKLOC,Gt Address Info.=6281106047;

CRSPCLGPA:SPAPLOC Name=”MAPVLR”,SPCLGPA,Include SPC=includeSPC FALSE,Include GT=includeGt TRUE,CLGPA Type Indicator=cgaAddressTypeIndicator programmed,NA=gtNatureOfAddress international,TTID=gtTranslationTypeLocal unknown,NP=gtNumberingPlan iSDNTNP,SPLNKLOC,Gt Address Info.=6281106047;

# InCP (Regen) :

CRSIGP:NETNO=3,NETNAME=NAT0,NETIND=NAT0,SPC=6317,SPCSTR=14,SDL=L272,NPV=ITU,TUPIND=TUP;

CRC7USER:USNAME=SCCP,DPC=6308,NETNAME=NAT0,PCMTYP=DIU30;

CRC7USER:USNAME=SCCP,DPC=6309,NETNAME=NAT0,PCMTYP=DIU30;

CRTGRP:TGNO=SBTBG,OPMODE=IC,GCOS=CCSLGRP;

CRTGRP:TGNO=SHMDN1,OPMODE=IC,GCOS=CCSLGRP;

CRINTCELL:LACOD=605,CI=33517,BSCSPC=6309,NETIND=NAT0,RC=BSC,LMN=C104,LOCNO=112;

MODENTOPT:VLRISD=6281106047,VLRNAME=”MMDN10″;

CRTRUNK:TGNO=SBTBG,LNO=1,LTG=1-55,LC=0-16,LCOS=DIGSIG8;

CRTRUNK:TGNO=SHMDN1,LNO=1,LTG=1-21,LC=1-1,LCOS=DIGSIG8;

  • Creation SCCP Remote on SSNC:

CRSPLNKREM:SPLNKREM,Net ID=3,DPC=6308;

CRSPLNKREM:SPLNKREM,Net ID=3,DPC=6309;

CRSPAPREM:SPAPREM Name=”06308#3#HL”,SPLNKREM,Local Broadcast=localBroadcast TRUE,Sccp Management=sccpManagement TRUE,SPAP Avail. Restart=ssAvailableAfterSpRestart TRUE,SSID=maphlr;

CRSPAPREM:SPAPREM Name=”06309#3#BS”,SPLNKREM,Local Broadcast=localBroadcast TRUE,Sccp Management=sccpManagement TRUE,SPAP Avail. Restart=ssAvailableAfterSpRestart TRUE,SSID=bssap;

CRSPENS:SPENS Name=”6308″,Primary 1,Sharing Mode=sharingMode solitary;

CRSPGTTRL:SPGTTRL Name=”LOCUPD”,NP=gtNumberingPlan lMNP,TTID=gtTranslationTypeLocal imsi,NA=gtNatureOfAddress international;

CRSPGTRUL:SPGTTRL Name=”LOCUPD”,SPGTRUL,GT Address Info.=5101060,SPENS Name=”6308″,Include SPC=FALSE,Possible Ported No.=FALSE,Traffic Type=Nat. Own;

Mobile to Mobile Call:

Basicly, DB for control connection/signalling process has already done in LOCUPD Process.

  • Creation user (voice) connection toward BSC

CRC7USER:USNAME=ISUP,DPC=6309,OSPC=6317,NETNAME=NAT0,PCMTYP=DIU30,CICSIZE=CIC14;

CRTGRP:TGNO=TBTBG,OPMODE=BW,ORIG1=50,GCOS=JSUBORD&NONSEQ&CCS7MUP&LPRIO5&AMAREQD&USVERS0&UNCZON,SIGVAR=VAR0;

ENTRC7TGREL:TGNO=TBTBG,DPC=6309,OSPC=6317,NETNAME=NAT0;

CRTRUNK:TGNO=TBTBG,CIC=0-1,LTG=1-32,LC=0-1,LCOS=DIGSIG4,TRRANGE=30;

CRTGRP:TGNO=MICOUT,OPMODE=OG,GCOS=NONSEQ&ECDPGRP&USVERS0,MGCOS=LOOPTRAF,SIGVAR=VAR0!

CRTGRP:TGNO=MICINC,OPMODE=IC,ORIG1=60,GCOS=JSUBORD&ECDPGRP&AMAREQD&USVERS0&UNCZON,MGCOS=LOOPTRAF&AMATRANS,SIGVAR=VAR0!

CRDEST:DEST=CUTOFF,CONVCOD=…..+0

CRDEST:DEST=MICLP1;

CRROUTE:DEST=MICLP,TGNO=MICOUT,ROUTE=1,LNDES=PRIM;

CRCPT:CODE=00162 (or another INAT PREFIX),ORIG=50,60,70,99,105,40, DEST=CUTOFF

CRCPT:CODE=00862 (or another INAT PREFIX),ORIG=50,60,70,99,105,40, DEST=CUTOFF

(Please check  DISP DNATT)

CRCPT:CODE=081160,DEST=MICLP,ORIG1=50-1;

CRCPT:CODE=081160,DEST=BLIND2,ORIG1=60-1,SYMCON=Y,TRATYP=MOBINTER;

Send Routing Info to HMDN1

CRSPGTTRL:SPGTTRL Name=”INTNAT”,NP=gtNumberingPlan iSDNTNP,TTID=gtTranslationTypeLocal unknown,NA=gtNatureOfAddress national;

CRSPGTRUL:SPGTTRL,SPGTRUL Name=”811600″,GT Address Info.=811600,SPENS Name=”6308″,Include SPC=FALSE,Possible Ported No.=FALSE,Traffic Type=Nat. Own;

Provide Roaming Number HMDN1 to MMDN11

CRSPGTTRL:SPGTTRL Name=”INTINT”,NP=gtNumberingPlan iSDNTNP,TTID=gtTranslationTypeLocal unknown,NA=gtNatureOfAddress international;

CRSPENS:SPENS,Primary 1 Name=”06310#3”;

CRSPGTRUL:SPGTTRL,SPGTRUL Name=”6281106049″,GT Address Info.= 6281106049,SPENS,Possible Ported No.=FALSE,Include SPC=FALSE,Traffic. Own;

PRN Ack MMDN11 to HMDN1

CRMSRNB:MSRNK=BOTH,MSRNR=3,MSRNP=8120470;

CRSPGTRUL:SPGTTRL,SPGTRUL Name=”6281106048″,GT Address Info.= 6281106048,SPENS,Possible Ported No.=FALSE,Include SPC=FALSE,Traffic. Own;

SRI Ack HMDN1 to MMDN10

CRSPGTTRL:SPGTTRL Name=”INTINT”,NP=gtNumberingPlan iSDNTNP,TTID=gtTranslationTypeLocal unknown,NA=gtNatureOfAddress international;

CRSPRNS:SPENS,Primary 1 Name=”06317#3”;

CRSPGTRUL:SPGTTRL,SPGTRUL Name=”6281106047″,GT Address Info.= 6281106047,SPENS,Possible Ported No.=FALSE,Include SPC=FALSE,Traffic. Own;

Digit Analysis based on MSRN in MMDN10

CRTGRP:TGNO=TMMDN11,OPMODE=BW,ORIGDC=20,ORIG1=20,GCOS=JSUBORD&NOZON&C7GLARE&CCS7IUP&AMAREQD&PROP0&PROP3&PROP5&PRIOPRE&USVERS1,SIGVAR=VAR0;

CRDEST:DEST=MSBY3;

CRROUTE:DEST=MSBY3,TGNO=TMSBY3,ROUTE=1,LNDES=ECNEEDED&PRIM;

CRCPT:CODE=0811029,DEST=MSCSB3,ORIG1=70-1;

Digit Analysis in MMDN11 receiving own MSRN in MMDN11

CEDEST:DEST=RSSN,MINMAX=10-11;

CRROUTE:DEST=RSSN,TGNO=BLIND,ROUTE=1,LNDES=PRIM;

CRCPT:CODE=0812047,DEST=RSSN,ORIG1=20-1,TRATYP=MOBBOTH;

Sumber: Siemens Indonesia.