Collection Statistic Data and Error Notebook From SND (SNMUX)

Prerequisite:
All SNMUX Status (ACT,STB,MBL,DST)

1. Connect the V24 cable (the same like for LTGN and MBD)
2. Start program „FITT“
3. Menu: COMMAND -> LOAD NEW LIBARY -> SERVICE2.LIB
4. Menu: COMPORT -> OPEN PORT
5. Menu: PROJECT -> LOAD FW PARAMETER ->MODULE TYPE -> MUXC
6. Menu: TERMINAL -> LOG FILE ( eq. SNMUX 0-0)
7. UT_CMD: HW/FW Version Show -> send command
The versions of the Current-User-FW and Backup-User-FW will be shown.
8. UT_CMD : Service short SHOW -> send command
All links status will be shown
9. UT_CMD : ENB_INIT -> send command
Reset old Error Notebook
10. UT_CMD : START SERVICE STATISTIC -> send command
– Wait 15 minutes if Status of SNMUX DST or MBL
– Wait 2 hours if Status of SNMUX ACT or STB
11. UT_CMD SHOW SERVICE STATISTIC -> send command
All Statistic Value Each Links will be Shown
12. UT_CMD ENB_READ -> send command
Error Notebook will be Shown
13. UT_CMD SHOW_FAILURE_NODES -> send command
SND Failure Node will be Shown
13.  EXIT FITT
14.  Send Log files to TAC2
16 Finished